Swing doors and gates
Product description
The Hodapp Tunnel Swing Gate (HTD) is used in the tunnel roadway area. In the event of a fire, the gate must be able to withstand external influences such as heat and smoke in order to prevent the fire from spreading.
HTD | |
Measurement range (RBM) Width: |
1.400-4.200 |
Height: | 2.000-4.900 |
Sheet thickness: | 123 |
Sheet thickness: | 1,5 |
Material: | Galvanized steel primed | painted, stainless steel 304 L (V2A) | 316 L (V4A) |
Automatic mode: | Ja |
Pressure relief aid: | Only wicket door |
Glazing: | Ja |
With wicket door: | Ja |
Fire resistance: | to EI2120 |
Smoke protection: | No |
Continuous function: | C0 |
Certificate of constancy of performance: | in 13241 in 16034 |
Pressure-suction resistance: | up to ±10 kPa |
Load change: | up to ±3 million |
Escape route signage: | only with a wicket door |
Frame: | 3- or 4-sided |
Installation in masonry: | 175 ≥ |
Installation in reinforced concrete: | 175 ≥ |